Tube rotameter (LFS-32d) liquid
structure
Structure diagram of plastic flowmeter: It is mainly composed of a transparent plastic tapered tube installed vertically with the small end down and the big end up and the float that can move up and down in the tapered tube as the measuring element, together with nuts, nozzles, stoppers and "O" rings, etc. constitute. The float is static when the fluid flows from bottom to top in the conical tube, and the buoyancy and viscous forces are in balance. When the flow rate changes, the flow velocity of the fluid flowing through the annular gap between the conical tube and the float changes, and the float pressure difference changes accordingly, and the float moves up and down, so the height of the float's resting position can be used as a measure of flow.
Install
(1) Before installation, the smooth support in the instrument should be gently removed with needle-nose pliers and then re-installed. When installing, pay attention to whether the rubber ring is installed in the groove of the nozzle to prevent water leakage.
(2) The interface of the flowmeter can be connected with a matching ABS plastic pipe or a PVC plastic pipe with a special dehydration bonding connection, or it can also be connected with a metal flange after being connected by a plastic method.
(3) The flowmeter must be installed vertically, at precisely 90 degrees. The installation height should be convenient for the reading of the float. When reading, the line of sight and the float should be level. (General standard: the optimal flow rate to be used is 50% to 70% of the maximum flow rate of the flowmeter, try not to use the highest number.)
(4) The upstream and downstream inlets of the device should ensure that there are straight pipe sections five times the diameter of the device.
(5) The fluid pressure to be measured must be stable. If the fluid pressure is unstable, the float will fluctuate and cannot be measured correctly. A buffer or a valuer should be installed upstream of the flowmeter.
LFS long pipe flowmeter specifications and parameters
Nominal diameter Model LFS Range Accuracy class Dimensions Plug tube Welded tube Normal temperature and pressure MPa Allowable temperature of the measured medium.
DN15
LFS-15 10-100L/H
16-160L/H
25-250L/H
40-400L/H
60-600L/H
Level 4
L
B1
B2
15
20
0.6MP2
0-50℃
DN25
LFS-25 100-1000L/H
160-1600L/H
250-2500L/H
300-3000L/H Grade 4
380
32
68
25
32
0.6MP2
0-50℃
DN50
LFS-50 400-4000L/H
0.6-6m3/H
1-10m3/H
2-16m3/H Four
class
435
63
98
50
63
0.4MPa
0-50℃
Dimensions of LFS short pipe flowmeter
Diameter Model Measuring Range Dimensions
Plug tube Welded tube
L B1 B2
DN15
LFS-15d 10-100L/H
16-160L/H
25-250L/H
60-600L/H
100-1000L/H
200
20
45
15
20
DN25
LFS-25d 100-1000L/H
160-1600L/H
250-2500L/H
226
32
60
25
32
DN32 LFS-32d 400-4000L/H
600-6000L/H 288 40 74 32 40
DN50 LFS-50d 1000-10000L/H
1600-16000L/H 341 63 98 50 63
DN65
LFS-65d 2-16m3/H
5-25m3/H
8-40m3/H
12-60m3/H
430
75
122
65
75